All,
 
We’ve talked at various times about wanting to be able to measure the synchronization accuracy of RoE equipment.  The 1PPS output signal is commonly used in telecom and test equipment; even some standard Ethernet switches with 1588 support have 1PPS outputs.
 
I think it would be good for the RoE spec to either encourage or require RoE equipment to provide the 1PPS output.  Here is some proposed text to consider:
RoE equipment should/shall provide a 1PPS output as described in clause A.1.3 and clause A.2 of ITU-T G.8271/Y.1366.
 
Clause A.1.3 talks about the timing of the 1PPS coinciding with the transition to a new second, and clause A.2 describes the 50-ohm 1PPS signal.
 
Feedback?
--kb
 
------------------------------------------------------------------